Checks computes every high-speed rule on the copper you routed. Interfaces groups those results by link — a USB port, an Ethernet PHY, a DDR byte lane — and adds the layout rules each specification publishes. Inspector shows one net or pair layer by layer. All three read the same run.

Running the checks#

Press Run checks (top right of the Workbench, or the button on Start here). The run happens in the background; the board stays editable. When it finishes the status line counts the results, and the Checks page lists them.

Checks after a run on h730duino: the USB pair fails its 90 Ω ±15 % target, with the evidence on the right
Checks after a run on h730duino: the USB pair fails its 90 Ω ±15 % target, with the evidence on the right
Control What it does
All · Signal integrity · Return path & EMI · Power · Interfaces Filters by category
Status chips (FAIL, WARNING, UNKNOWN, NOT RUN, PASS) Show or hide each status
filter Narrows by net, pair or rule name
Suggest fixes for all Turns every failing result into a proposed fix on the Fixes page
Auto (top bar) The impedance method: closed forms, with the field solver wherever a result is close to its limit

What a status means#

Status Meaning
PASS Computed, inside its limit, and nothing it depends on is assumed
WARNING Inside a soft limit, close to a hard one — or computed on an assumed stack-up
FAIL Outside a hard limit
UNKNOWN Something the rule needs is missing (a rise time, a load step, an aggressor's edge) — it is never shown as PASS
NOT RUN The rule has nothing to measure yet (the net is not routed)
STALE The board changed after the run; press Run checks again

Reading one result#

Pick a result to see how it was computed. The right-hand card shows:

  • Result — the measured value, for example 107.8 Ω on F.Cu (w 0.152 mm, gap 0.157 mm).
  • Rule and Rule id — the limit and where it lives (zdiff@interface:usb2-hs-1).
  • Basis — Specification, Vendor guideline, Physics or Rule of thumb, with the source quoted: here Renesas R01AN5119, "a differential impedance of 90 ohm ±15 %".
  • Inputs — the target, each layer the net runs on with its own value, and the value at fab tolerance (on h730duino the USB pair is 97.3–119.0 Ω across the board house's corners — outside the window even at its best corner).
  • Method — for example WireFrame 2D field solver: quasi-static finite-volume Laplace on graded meshes, Richardson-extrapolated.
  • Assumptions — quasi-static (TEM), lossless, copper as rectangles…

Buttons under the result: Show on board (selects and frames the copper on the canvas), Suggest a fix, Inspect (opens the net in the Inspector) and Copy (the result as text, for a review or an issue).

What is checked#

Rule Default limit How it is measured
Impedance (single and differential) The class's target and tolerance Each layer's routed geometry, closed form or 2D field solver
Pair skew The class's limit, in length or in time Each leg's length per layer × that layer's delay
Length / time matching The group's tolerance Against the group's reference net
Via count, stub length The class's limits Vias on the net; the unused barrel below the last layer used
Return path No length over a gap The reference plane under each segment, from the poured copper
Plane edge 6.3 × the height above the plane Rays sideways from the track to the reference pour's edge (holes under 2 mm ignored)
Return via 1.27 mm A via that moves the net between reference planes needs a stitching via (same net) or a capacitor (different nets) beside it
Crosstalk 5 % of the aggressor's swing (a class can ask less) Every parallel run on the same layer within 10 × the height; near-end saturates, far-end grows with length; all aggressors at once. No aggressor edge rate → an upper bound marked UNKNOWN
Decoupling 3 mm pin to capacitor Every IC supply pin on the rail to the nearest rail-to-ground capacitor
PDN impedance V × ripple / ΔI See Power
Current capacity The rail's DC current IPC-2221 (10 °C rise) on the rail's narrowest track
Emission 6 dB under the chosen limit See EMI
Insertion loss The interface's budget at Nyquist Conductor loss (with roughness) + dielectric loss per layer

Interfaces#

Each link is checked against the layout requirements its specification or its silicon vendors publish, one row per requirement, each with its source.

USB 2.0 High-Speed and two Ethernet ports on h730duino, each row with its source; RGMII, OCTOSPI and SD/eMMC recognised below
USB 2.0 High-Speed and two Ethernet ports on h730duino, each row with its source; RGMII, OCTOSPI and SD/eMMC recognised below

Profiles shipped: USB 2.0 HS, USB 3.x, PCIe, Ethernet MDI, HDMI, MIPI D-PHY, LVDS, SATA, DDR3/DDR4 byte lane, RGMII, Quad/Octal SPI and SD/eMMC. Examples of what they cite: USB 2.0 from Renesas R01AN5119 (90 Ω ±15 %, 2.5 mm skew, no vias, plane 1 mm wider, 3 × S guard); Ethernet MDI from TI SNLA387 (100 Ω ±10 %); DDR4 DQ to DQS ±3.5 ps in time (Intel Agilex 7 EMIF); RGMII TXD within 11 ps (TI DP83867). A number no document gave is marked rule of thumb.

On h730duino, USB 2.0 HS meets 1 of its 7 requirements and the two Ethernet MDI ports 0 of 3. Groups WireFrame recognised but nobody has declared yet — RGMII, OCTOSPI, SD/eMMC — are listed under them, each with Check.

Layout compliance is necessary, not sufficient

Meeting every row here means the copper follows the published layout rules. Whether the link passes its own electrical compliance test is decided by that test, on hardware. The Workbench prints this wherever it says "compliance".

Inspector#

One net or one pair, layer by layer: what it is made of, what its copper computes to, and every result that names it.

The Inspector on /USB_OTG_HS_P: 3515 mil, 504 ps, 2 vias, 119.78 mil over no plane; the pair's skew and coupling
The Inspector on /USB_OTG_HS_P: 3515 mil, 504 ps, 2 vias, 119.78 mil over no plane; the pair's skew and coupling

On h730duino, /USB_OTG_HS_P is 3515 mil long, 504 ps of delay, through 2 vias, and runs 119.78 mil over no plane. Its two halves differ by 101.81 mil (14.6 ps) and run side by side for only 88 % of their length.

While you route#

For a net with high-speed rules, the routing readout beside the cursor gains the same measurements, for the track being drawn:

  • the return path — which plane is under the new segment, and how much of it runs over none;
  • the plane edge, measured sideways from the track;
  • the whole net's crosstalk against the copper beside it;
  • and the fix for the worst finding.

They are the checks' own measurements on the pours as filled, so the number while drawing and the number after the run are the same number. See Length tuning and differential pairs for routing pairs and adding meanders.

Pitfalls#

  • Everything is WARNING. The stack-up is still ASSUMED. Enter your board house's stack-up on Stack-up and tick I confirmed this with my board house.
  • A crosstalk or PDN result is UNKNOWN. It needs an input nobody stated: the aggressor's rise time (on the net class or the interface), or the rail's load step. Stating it is a fix of its own (set_rail, set_interface), approved like any other.
  • A newly declared interface reads "not routed". It is measured as soon as the declaration is previewed; run the checks again after applying it.
  • Return-path results changed after a pour. They read the planes as filled — refill zones (Zone Manager) before trusting them.